Published Nov 4, 2026 · Last reviewed Nov 4, 2026

Watts versus watt-hours
Watts (W) are a rate: how much power a device draws at a moment. Watt-hours (Wh) are an amount: how much energy is used or stored over time. A 40 W device running for 8 hours uses 320 Wh. Battery capacity is quoted in Wh. If you only know amp-hours and volts, multiply them: the FAA's battery guidance gives the example of a 12 V, 8 Ah battery holding 96 Wh.
The formula we use
Energy per device = running watts × quantity × hours per day (× duty cycle for appliances that cycle on and off).
Required battery capacity = total energy ÷ conversion efficiency × (1 + safety margin).
The U.S. Department of Energy uses the same first step for estimating daily appliance energy: wattage × hours used per day ÷ 1,000 gives kilowatt-hours per day.
Worked example: one day off-grid
| Device | Watts | Qty | Hours/day | Wh/day |
|---|---|---|---|---|
| Phone charging | 15 | 1 | 3 | 45 |
| Laptop | 65 | 1 | 5 | 325 |
| LED bulbs | 10 | 4 | 5 | 200 |
| CPAP (no humidifier) | 40 | 1 | 8 | 320 |
| Total | 890 |
With our default assumptions of 85% conversion efficiency and a 20% safety margin: 890 Wh ÷ 0.85 × 1.2 = 1,257 Wh. For two days, it doubles the energy: 1,780 Wh ÷ 0.85 × 1.2 = 2,513 Wh.
The wattages above are the calculator's starting values, not measurements of your devices. Replace them with label figures or meter readings. For example, ResMed's own measurements for the AirSense 10 list about 7 watt-hours per hour for the device alone, rising to 22 with the humidifier and 34 with a heated tube, at the settings in its document.
Why divide by efficiency?
Some energy is lost converting the battery's DC to household AC. Sandia National Laboratories notes that inverter efficiency changes with output power and voltage. Manufacturers of the portable units in our database do not publish inverter efficiency, so 85% is our planning assumption, not a measured figure. You can change it in the calculator.
Why add a margin?
Usable capacity falls as a battery ages and in cold weather, appliance draw varies, and you rarely want to run a battery to empty. A 20% margin is a planning cushion, not a technical constant. Raise it for medical or critical loads.
Capacity is only half of sizing
Also check continuous AC output (the total watts of everything running at once) and, for motors, surge. In the example above, the devices together draw 80 W if all are on, which any unit in our database can supply, but a microwave would change that completely.
Try it with your own numbers
Open the calculator, tick your devices, and replace the default watts and hours with your own. It shows the formula it used and lists only products whose published specs meet the result.
Ready to put numbers on it?
Open the calculatorSources
- Estimating Appliance and Home Electronic Energy Use. U.S. Department of Energy, Energy Saver.
- Airline Passengers and Batteries (PackSafe). Federal Aviation Administration.
- CEC Inverter Test Protocol. Sandia National Laboratories, PV Performance Modeling Collaborative.
- Power consumption of Air10 devices. ResMed.
Related guides
We have not physically tested any product mentioned. Specifications come from manufacturer pages and manuals; calculations are estimates. See our methodology.
← All guides