Published Nov 4, 2026 · Last reviewed Nov 4, 2026

Back up essentials, not the house
The EIA puts average U.S. household use at about 10,500 kWh a year, roughly 28.8 kWh a day. Even the largest single unit in our database, the EcoFlow DELTA Pro 3 at 4,096 Wh, stores about 14% of that. Plan around a short list of essentials.
Example: one outage day of essentials
| Load | Basis | Wh/day |
|---|---|---|
| Refrigerator | EIA 2020 average, most-used fridge (617 kWh/yr) | 1,690 |
| Wi-Fi router | 12 W adapter ceiling × 24 h | 288 |
| LED lighting | 4 × 10 W × 6 h | 240 |
| Phones | 2 × 15 W × 2 h | 60 |
| CPAP with humidifier | about 22 Wh per hour × 8 h (AirSense 10) | 176 |
| Total | 2,454 |
With our planning assumptions (85% efficiency, 20% margin): 2,454 ÷ 0.85 × 1.2 = 3,465 Wh for one day. Use your own label figures; this example is meant to show the scale.
Medical devices come first
The FDA's outage guide for home medical devices suggests asking the device manufacturer or your provider whether the device can run on batteries, how long it lasts on battery power, and whether it has a backup option. It also suggests telling your power company that you use a power-dependent device. Confirm with the device maker that it is suitable to run from the power station's AC outlet before relying on it.
Never backfeed your house wiring
CPSC warns against plugging a generator into a wall outlet to power house wiring, called backfeeding, because it is an electrocution risk to utility workers and neighbors. OSHA and FEMA say connections to a building's wiring should go through a transfer switch installed by a qualified electrician. The same hazard applies to any AC source, including a power station. If you want a power station to feed selected circuits, use the manufacturer's approved transfer equipment and have an electrician install it.
Recharging during a long outage
Without grid power you need another way to recharge: solar panels within the station's input limits, a vehicle's 12 V socket (slow), or a generator run safely outdoors. Read Solar charging explained and the generator comparison.
A preparation checklist
- List essential loads and their real daily energy.
- Size with the calculator and add margin for medical loads.
- Keep the station charged; check it every few months.
- Plan a recharge method that works without grid power.
- Never connect any power source to house wiring without a transfer switch installed by an electrician.
Ready to put numbers on it?
Open the calculatorSources
- Electricity use in homes. U.S. Energy Information Administration.
- Table CE5.3b: Detailed household site electricity end-use consumption, averages, 2020 (RECS). U.S. Energy Information Administration.
- Home Use Devices: How to Prepare for and Handle Power Outages for Medical Devices that Require Electricity. U.S. Food and Drug Administration.
- Portable Generator Safety Alert (CPSC 5123). U.S. Consumer Product Safety Commission.
- Using Portable Generators Safely (Fact Sheet). Occupational Safety and Health Administration.
- Fact Sheet: Be Safe When Using a Portable Generator. FEMA.
- Maximum power consumption for NETGEAR WiFi Routers. NETGEAR.
- Power consumption of Air10 devices. ResMed.
- Power Station Advisor product database (manufacturer specifications, checked Nov 4, 2026). Power Station Advisor.
Related guides
We have not physically tested any product mentioned. Specifications come from manufacturer pages and manuals; calculations are estimates. See our methodology.
← All guides